datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:HP an 380-1

HP an 380-1 free download

Various electronics service manuals

File information:
File name:an_380-1.pdf
[preview an 380-1]
Size:3529 kB
Extension:pdf
Mfg:HP
Model:an 380-1 🔎
Original:an 380-1 🔎
Descr: HP Publikacje an_380-1.pdf
Group:Electronics > Other
Uploaded:31-01-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name an_380-1.pdf

Dielectric Constant Measurement of Solid Materials Application Note 380-1 Using HP 16451B Dielectric test fixture 1 Introduction (2) Additional Measurement Errors can be Corrected. To improve the quality of the dielectric solid mate- rials such as polymer, electric insulator, PC board, Stray admittance and residual impedance of the ceramic substrate etc., it is very important to eval- test fixture are the error sources in a dielectric uate their electrical and physical characteristics, constant measurement. The HP 16451B can elimi- such as molecular structure and density. The die- nate these additional error factors with the lectric constant measurement is a very popular OPEN/SHORT error correction function of the evaluation method. Using the HP 16451B Dielectric measurement instrument by using the furnished Test Fixture with an HP LCR meter/Impedance OPEN/SHORT attachment. Edge capacitance is Analyzer, accurate and easy dielectric constant and another error source (Figure 1). The HP 16451B dissipation factor (tan ( ))1 measurements are can also eliminate the edge capacitance error by possible. This application note explains the fea- using a guarded electrode (3-Terminal method). tures and benefits of the HP 16451B and measure- ment methods, and shows an example of measuring a plate type dielectric materials. Dielectric Constant Measurement Problems The dielectric constant is calculated from the C-D (Capacitance and Dissipation factor) measurement results using an HP LCR meter/Impedance ana- lyzer. However, there were many problems in the realization of precise C-D measurement and easy connections between the measurement instrument Edge Capacitance and the test fixture. Thus dielectric constant meas- urement was difficult. Figure 1. Additional Error Due to Edge Capacitance HP 16451B Main Features and Benefits (3) Interchangeable Electrodes (1) The HP 16451B can be connected directly to 4-Terminal Pair measurement instruments. If a test fixture has only one type of electrode, it is necessary to adjust the size of the Material Under The 4-Terminal Pair measurement method adopted Test (MUT) or to form thin film electrodes on the in recent impedance measurement instruments surface of the MUT. offers accurate measurement

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
HP a-122 - HP an 1237-1 - HP 13255-91018 Keyboard Module Aug76 - HP an 1287-1 - HP 5968-3411E - HP 13220-91097 2624 Processor Module Apr81 - HP 13255-91123 Extended Keyboard Interface Module Aug76 -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Sansui AE550, AE750

script execution: 0.05 s